Remote Sensor Heads

These are used when it becomes difficult or impossible for the standard valve to sense air temperature correctly, such as behind furniture or curtains or when it is in direct sunlight. The TRV 2Way Remote Sensor head is set exactly as a standard head, except that a length of capillary tubing connects the sensing element to the head control.

The TRV range provides for a choice of capillary length, either 2m or 5m.

 

An alternative is the remote adjuster that may be used on applications where the control is required to be remote from the heating radiator that it is controlling. The product range provides for a choice of capillary length, 2m or 5m.