Premier HE
Myson Premier HE stylish round top radiators in imperial sizes
- Stylish, hazard-reducing round top
- Impressive heat outputs
- Suitable for low temperature systems
- Numerous sizes available
- Imperial sizes for retrofitting
Product description
Myson Premier HE is famous for its round top which not only provides extra safety, but also gives the Premier HE radiator its unique style and good looks. As the only UK panel radiator range offering imperial fitting dimensions, Myson's Premier HE is the perfect panel radiator for retro fitting projects. The Myson Premier Metric offers the same great looks high performance, but in metric sizes. Also available with factory fitted top grille and side panels - see Premier Compact.
Technical Specifications
| ETIM Class | EC011022 - Panel radiator |
|---|---|
| Material | Steel |
| Type | 11 - 21 - 22 |
| Surface structure front side panel | Profiled |
| Water-bearing front panel | Yes |
| Suitable for damp space | No |
| Height [mm] | 300 - 690 |
| Length [mm] | 286 - 2165 |
| Depth [mm] | 50 - 106 |
| Heat emission according to EN 442 20 °C - 55/45 [W] | 1.002 - 990 |
| Heat emission according to EN 442 20 °C - 75/65 [W] | 1.005 - 985 |
| Heat emission according to EN 442 20 °C - 70/40 [W] | 120 - 2007 |
| Heat emission according to EN 442 laboratory | Yes |
| N-exponent | 1.2692 - 1.3246 |
| Max. operating pressure [bar] | 5.4 |
| Water content [l] | 1 - 18 |
| Standard colour | Yes |
| Colour | White |
| RAL-number | 9016 |
| Degree of gloss | Glossy |
| Welded-on strips | Yes |
| With side lining | No |
| With top cladding | No |
| Collapsible | No |
| Number of standard connections | 2 - 4 |
| Connection 1, bottom left | Inlet/outlet flow |
| Connection 3, left side top | Inlet flow |
| Connection 5, top right | Inlet flow |
| Connection 8, bottom right | Inlet/outlet flow |
| Thread size (inch) | 1/2 inch |
| Thread connection | Internal thread |
| With single-point connection | No |
| With de-aeration connection | Yes |
| With de-aerator | Yes |
| With drain possibility (connection) | Yes |
| With drain valve | No |
| With integrated thermostatic valve | No |
| With wall brackets | Yes |
| Suitable for electrical element | No |
| With electrical element | No |
| With blind stops | Yes |
| With mounting material | Yes |
| With towel holder | No |
| Recessed towel holder | No |
| Watt Per Meter [W/m] | 515 - 1999 |
| Factor K | 1.391 - 19.753 |
| Watt Absolute [W] | 0 |
| Heat emission according to EN 442 20 °C – 55/45 [Btu/h] | 356 - 6099 |
| Heat emission according to EN 442 20 °C – 75/65 [Btu/h] | 680 - 11997 |
| Max. Operating Temperature [°C] | 100 |
| Mounting Direction | Horizontal |
| Number of wall brackets | 2 - 3 |
| Weight [kg] | 1.126 - 64.16 |