Product description

Myson Premier HE is famous for its round top which not only provides extra safety, but also gives the Premier HE radiator its unique style and good looks. As the only UK panel radiator range offering imperial fitting dimensions, Myson's Premier HE is the perfect panel radiator for retro fitting projects. The Myson Premier Metric offers the same great looks high performance, but in metric sizes. Also available with factory fitted top grille and side panels - see Premier Compact.

Technical Specifications

ETIM Class EC011022 - Panel radiator
Material Steel
Type 11 - 21 - 22
Surface structure front side panel Profiled
Water-bearing front panel Yes
Suitable for damp space No
Height [mm] 300 - 690
Length [mm] 286 - 2165
Depth [mm] 50 - 106
Heat emission according to EN 442 20 °C - 55/45 [W] 1.002 - 990
Heat emission according to EN 442 20 °C - 75/65 [W] 1.005 - 985
Heat emission according to EN 442 20 °C - 70/40 [W] 120 - 2007
Heat emission according to EN 442 laboratory Yes
N-exponent 1.2692 - 1.3246
Max. operating pressure [bar] 5.4
Water content [l] 1 - 18
Standard colour Yes
Colour White
RAL-number 9016
Degree of gloss Glossy
Welded-on strips Yes
With side lining No
With top cladding No
Collapsible No
Number of standard connections 2 - 4
Connection 1, bottom left Inlet/outlet flow
Connection 3, left side top Inlet flow
Connection 5, top right Inlet flow
Connection 8, bottom right Inlet/outlet flow
Thread size (inch) 1/2 inch
Thread connection Internal thread
With single-point connection No
With de-aeration connection Yes
With de-aerator Yes
With drain possibility (connection) Yes
With drain valve No
With integrated thermostatic valve No
With wall brackets Yes
Suitable for electrical element No
With electrical element No
With blind stops Yes
With mounting material Yes
With towel holder No
Recessed towel holder No
Watt Per Meter [W/m] 515 - 1999
Factor K 1.391 - 19.753
Watt Absolute [W] 0
Heat emission according to EN 442 20 °C – 55/45 [Btu/h] 356 - 6099
Heat emission according to EN 442 20 °C – 75/65 [Btu/h] 680 - 11997
Max. Operating Temperature [°C] 100
Mounting Direction Horizontal
Number of wall brackets 2 - 3
Weight [kg] 1.126 - 64.16